Feature:
1.Siphoning type electrode(Earthlong Patent), really test each side effectively。
2. Easy operation; Super test area; Result display two mode data and Image.
3.Read quickly; Data error ±1mv;
4. Nine gray scientific grade; Color display of the corrosion range.
5. Special analysis software; reporting auto and drafting electric potential diagram.
Main Specification:
1. Test electric potential:±1000mv。
2. Test precision:±1mv。
3. Reading Storage:228000 readings
4. Test Area:Max 1600m2。
5. Set point distance:1—60cm optional
6. Work temperature: 0—40℃;Humidity:<85%。
7. Power:9VDC(Six AA batteries );Work time >30 hour
8. Host Size:225×180×80(mm);Probe:φ30×180(mm) |