Main Features:

features description                                                              
High Accuracy measuring Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1%
Non-intrusive
measuring  
Non-intrusive, clamp-on transducer, no pressure drop, no pipe disturbance.
Wide measuring
range
Several types transducer for selection, measuring pipe size
from DN15mm to DN6000mm
Chinese & English menu Chinese & English display, easy to operate.
Large capacity
battery
Built-in rechargeable Ni-MH rechargeable battery, provide over 20 hours of continuous operation 
Built-in printer Built-in printer with instant and timing print function
Built-in data logger Uplink over 20 measuring data to computer or internet

Standard configuration:  

mainunit 1
medium  transducer      TM1                     1
special cable 1
power cord 1
carrying case 1
strecher 1
tape ruler 1
thermal paper 1
user manual 1
ultrasonic coupling agent 1

Optional  configuration

1.ultrasonic thickness meter 2.lengthen cable 3.lengthen strentcher 4. thermal paper

General Specification

items specifications                                                    
main unit                

1. 2 line*20 character LCD with backlight Woking temperature:-25--60℃                      2. Mini thermal printer with 24 line cgaracter output                                                            3.   4*4+2 pushbutton keypad                     RS-485 interface for networking

transducer options TS-1:small size transducer (magnetic) for pipe size DN15-100mm ,liquid temperature≤110℃                                                       TM-1: medium size transducer(mannetic) for pipe size DN50-1000mm,liquid temperature≤110℃
liquid types water sea water industrial sewage, acid and alkali liquid, various oils etc. liquid which can transmit sound wave
flow velocity range 0-±30m/s
accuracy Better than ±1%
power supply  Built-in rechargeable Ni-MH battery (for 20 hours operation) orAC 220V
power consumption 1.5W
charging  Intelligent charging with AC 220V
weight Net weight: 2.5kg (main unit)
remarks With a high strength carrying case suitable for normal and harsh environment