RANGE 0~ 9999mm (at steel velocity); range selectable in fixed steps or continuously variable. PULSER Spike excitation with low, middle and high choices of the pulse energy. Pulse Repetition Rate: manually adjustable from 10 to 1000 Hz. Pulse width: Adjustable in a certain range to match different probes. Damping: 100Ω, 200Ω, 400Ω selectable to meet different resolution and sensitivity need. Probe work mode: Single element, dual element and through transmission; RECEIVER Real-time sampling at 160MHz high speed enough to record the defect information. Rectification: Positive half wave, negative halfwave, full wave, and RF DB Step: 0dB, 0.1 dB, 2dB, 6dB step value as well as auto-gain mode ALARM Alarm with sound and light,.
MERMORY Total 100 configuration channels store all instrument operating parameters plus DAC/AVG curve; stored configuration data can be easily previewed and recalled for quick, repeatable instrument setup. Total 1000 datasets store all instrument operating parameters plus A-scan. All the configuration channels and datasets can be transferred to PC via USB port. FUNCTIONS Peak Hold: Automatically searching the peak wave inside the gate and hold it on the display. Equivalent diameter calculation: find out the peak echo and calculate its equivalent diameter. Continuous Record: Record the display continuously and save it to the memory inside the instrument. Defect Localization: Localize the defect position, including the distance, the depth and its plane projection distance. Defect Sizing: calculate the defect size Defect Evaluation: Evaluate the defect by echo envelope. DAC: Distance Amplitude Correction
AVG: Distance Gain Size curve function Crack measure: Measure and calculate the crack depth B-SCAN: Display the cross-section of the test block. REAL-TIME CLOCK Real time clock for tracking the time. COMMUNICATION USB2.0 high-speed communication port SPECIFICATIONS Range: (0 ~ 9999) mm Bandwidth: (0.5 ~ 15) MHz Material Velocity: (1000 ~ 9999) m / s Dynamic Range: ≥ 32dB Vertical linear error: ≤ 3% Horizontal linear error: ≤ 0.2% Resolution:> 40dB (5P14) Sensitivity Leavings: 60dB (flat-bottomed deep hole 200mmФ2) Rejection: (0 to 80)% Linear Noise level: ≤ 10% Power supply: DC 9V; lithium batteries work for 4 to 8 hours or more
Ambient temperature: (-20 ~ 50) ℃ Relative Humidity: (20 ~ 95)% RH Overall dimensions: 263 × 170 × 61 (mm) MFD510 Standard Configuration
| Main Body |
1 |
| Straight Beam Probe |
1 |
| Angle Probe |
1 |
| Machine-probe Cable (Q9-Q9) |
1 |
| Battery Module |
1 |
| Power Adapter (Charger) |
1 |
| Support Pillar |
1 |
| Manual |
1 |
| Instrument Case |
1 |
| Datapro Software |
1 |
| USB communication Cable |
1 | |